Follow us :

Membrane geometries

time2013/04/22

Spiral wound module:
Consists of large consecutive layers of membrane and support material rolled up around a tube. Maximizes surface area.

Less expensive, however, more sensitive to pollution.
Tubular membrane:
The feed solution flows through the membrane core and the permeate is collected in the tubular housing.
Generally used for viscous or bad quality fluids.
System is not very compact and has a high cost per unit area installed
Hollow fiber membrane:
The modules contain several small (0.6 to 2 mm diameter) tubes or fibers.
The feed solution flows through the open cores of the fibers and the permeate is collected in the cartridge area surrounding the fibers.
The filtration can be carried out either “inside-out” or “outside-in”